Product Overview
ECCU44 End Column Cap with Uplift
The ECCU is designed for column-beam connections in end-of-beam applications requiring uplift values. The seat of the column cap provides additional surface area for bearing that extends beyond one side of the column. The ECCU helps to distribute the load from the beam and provide support for the connection.
Key Features
- Certified welds for confidence in strength and loading
- Uplift loads increased for earthquake or wind loading
- Bolt spacing that meets NDS code requirements to ensure optimal performance
- Diamond holes to provide temporary fastening
Material
- ECCU 5/8, ECCU44 — 7 gauge; ECCU 3/4 — 3 gauge
Finish
- Simpson Strong-Tie gray paint
Installation
- Use all specified fasteners; see General Notes
- Bolt holes shall be a minimum of 1/32" to a maximum of 1/16" larger than the bolt diameter (per 2018 NDS, section 12.1.3.2); bolt holes should be drilled from one side all the way through the beam to maintain hole tolerances
- Contact engineered wood manufacturers for connections that are not through the wide face